Physical Specifications | |
Backplane | 320 Gbps Virtual Chassis Interconnect To Combine Up To 10 Units As A Single Logical Device |
Uplink Module Options | 4-Port Dual-Mode 10GbE/1GbE Module With Pluggable SFP+/SFP Optics |
Dimensions (W X H X D) |
|
Weight |
|
Rack Mountable | 1 Rack Unit |
Hardware Specifications | |
Switching Engine Model | Store And Forward |
DRAM | 2 GB With Error Correcting Code (ECC) |
Flash | 2 GB |
CPU | 1.5 GHz Dual-Core PowerPC CPU |
GbE Port Density Per System | 56 (48 Host Ports + Four 40GbE Ports + Optional Fourport 1/10GbE Uplink Module) |
10GbE Port Density Per System | 4 (Uplink Module) |
40GbE Port Density Per System | 4 |
Packet Switching Capacities (Maximum With 64 Byte Packets) | 248 Gbps (Unidirectional)/496 Gbps (Bidirectional) |
Layer 2/Layer 3 Throughput (Mpps) (Maximum With 64 Byte Packets) | 369 Mpps (Wire Speed) |
Supported Optics |
|
Physical Layer |
|
Power Options | |
Power Supply Rating | 1100 W AC Dual Load-Sharing Hot-Swappable Internal Redundant Power Supplies |
PoE Budget | 900 W |
Maximum Current Inrush | 50 Amps |
Minimum Number Of PSUs Required For Fully Loaded Chassis | 1 Per Switch |
Environment | |
Operating Temperature | 32° To 113° F (0º To 45º C) |
Storage Temperature | -40º To 158º F (-40º To 70º C) |
Relative Humidity (Operating) | 10% To 85% (Noncondensing) |
Relative Humidity (Non-Operating) | 0% To 95% (Noncondensing) |
Altitude (Operating) | Up To 10,000 Ft (3,048 M) |
Altitude (Non-Operating) | Up To 16,000 Ft (4,877 M) |
Cooling | |
Cooling Airflow | AFO (Front-To-Back Airflow) |
Field-Replaceable Fans | 2 |
Airflow | PSU-7.5 Cubic Feet Per Minute (CFM); Fan-22 CFM |
Total Maximum Airflow Throughput With Two Power Supplies | 59 CFM |
Noise Specifications | |
Noise Specifications | Noise Measurements Based On Operational Tests Taken From Bystander Position (Front) And Performed At 23° C In Compliance With ISO 7779 |
Acoustic Noise In DBA | 51.0 |
Safety And Compliance | |
Safety Certifications |
|
Electromagnetic Compatibility Certifications |
|
NEBS | GR-1089-Core: EMC And Electrical Safety For Network Telecommunications Equipment |
Environmental | Reduction Of Hazardous Substances (ROHS) 6/6 |
Telco | CLEI Code |