Cisco 3064-X Switch for Sale

200,000.00

Description

Physical ●  1RU Fixed Form Factor

●  Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+)

◦   48 SFP ports support 1 and 10 Gigabit Ethernet

◦   4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each

●  2 redundant power supplies

●  1fan tray with redundant fans

●  1 I/O module with management, console, and USB flash memory ports

Performance ●  1.28-Tbps Switching Capacity

●  Forwarding rate of 950 mpps

●  Line-rate traffic throughput (both Layer 2 and 3) on all ports

●  Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames)

Hardware Tables And Scalability MAC Addresses 128,000
Number Of VLAN’S 4096
Spanning-Tree Instances ●  Rapid Spanning Tree Protocol (RSTP): 512

●  Multiple Spanning Tree (MST) Protocol: 64

ACL Entries ●  2000 Ingress

●  1000 egress

Routing Table ●  16,000 Prefixes And 16,000 Host Entries

●  8000 multicast routes

Number Of EtherChannels 64 (With PC)
Number Of Ports Per EtherChannel 32
Buffers 9 MB Shared
Boot Flash Memory 2 GB
Power Number Of Power Supplies 2

●  Cisco Nexus 3064-X: Redundant for AC and DC power

Power Supply Types ●  AC (Forward And Reversed Airflow)

●  DC (forward and reversed airflow)

Typical Operating Power ●  Cisco Nexus 3064-X

◦   143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs])

◦   177W (64p with SR optics at 100% load; 2 PSUs)

Maximum Power ●  Cisco Nexus 3064-X: 199W
AC PSUs

●  Input voltage

●  Frequency

●  Efficiency

 

●  100 to 240 VAC

●  50 to 60 Hz

●  89 to 91% at 220V

DC PSUs

●  Input voltage

●  Maximum current

●  Efficiency

 

●  -40 to -72 VDC

●  33A

●  85 to 88%

Typical Heat Dissipation ●  Cisco Nexus 3064-X

◦   488 BTU/hr (64p with Twinax at 100% load; 2 PSUs)

◦   605 BTU/hr (64p with SR optics at 100% load; 2 PSUs)

Maximum Heat Dissipation ●  Cisco Nexus 3064-X: 683 BTU/Hr
Cooling Forward And Reversed Airflow Schemes:

●  Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)

●  Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)

Single fan tray with redundant fans

Hot-swappable (must swap within 1 min)

Sound Measured Sound Power (Maximum)

●  Fan speed: 40% duty cycle

●  Fan speed: 60% duty cycle

●  Fan speed: 100% duty cycle

 

●  59.7 dBA

●  66.4 dBA

●  71.0 dBA

Environment Dimensions (Height X Width X Depth) ●  Cisco Nexus 3064-X: 1.72 X 17.3 X 19.7 In. (4.4 X 43.9 X 50.5 Cm)
Weight ●  Cisco Nexus 3064-X: 20.5 Lb (9.3 Kg)
Operating Temperature 32 To 104°F (0 To 40°C)
Storage Temperature -40 To 158°F (-40 To 70°C)
Operating Relative Humidity ●  10 To 85% Noncondensing

●  Up to 5 days at maximum (85%) humidity

●  Recommend ASHRAE data center environment

Storage Relative Humidity 5 To 95% Noncondensing
Altitude 0 To 10,000 Ft (0 To 3000m)